ONC g10 certification is certification to §170.315(g)(10), the Standardized API criterion. An ONC-Authorized Testing Lab tests your FHIR R4 API with the Inferno (g)(10) test kit, an ONC-approved test method. The API must serve USCDI data through US Core, authorize apps with SMART App Launch, and export patient groups with FHIR Bulk Data.
An ONC-Authorized Certification Body then issues the certification, and the product is listed on the CHPL. The regulatory baseline is US Core 6.1.0, SMART App Launch 2.0.0, and Bulk Data 1.0, with newer versions allowed through ONC's Standards Version Advancement Process. The criterion text is at 45 CFR 170.315(g)(10). For the wider program (testing labs, certification bodies, CHPL, Conditions of Certification), start with our ONC Health IT certification guide.
What does §170.315(g)(10) require?
The criterion requires a read-only, standards-based API with eight parts: single-patient and multi-patient data responses, search, app registration, secure connections, authentication and authorization, patient-directed revocation, token introspection, and documentation. Most parts point at a standard in 45 CFR 170.215; registration, revocation, and documentation are functional requirements.
| Paragraph | What it requires | Standard it points to |
|---|---|---|
| (g)(10)(i)(A) | Respond to single-patient requests for every USCDI data element, supporting all "mandatory" and "must support" elements | FHIR R4.0.1, US Core 6.1.0 Server CapabilityStatement |
| (g)(10)(i)(B) | Respond to requests for multiple patients' data as a group | FHIR Bulk Data Access v1.0.0 STU 1, "group-export" |
| (g)(10)(ii) | Support the required US Core searches (single patient) and Bulk Data search criteria (multiple patients) | US Core 6.1.0, Bulk Data |
| (g)(10)(iii) | Let an app register with the authorization server | No standard; you demonstrate your process |
| (g)(10)(iv) | Secure, trusted connections for patient, user, and system scopes | SMART App Launch 2.0.0, Bulk Data |
| (g)(10)(v) | Authenticate and authorize first-time connections, issuing refresh tokens valid at least three months to confidential apps and to native apps that can secure one; on later connections, grant access with a valid refresh token without re-authentication and issue confidential apps a new refresh token valid another three months; backend services auth for system scopes | SMART App Launch 2.0.0, OpenID Connect Core 1.0 (errata set 1), Bulk Data "SMART Backend Services: Authorization Guide" |
| (g)(10)(vi) | Revoke an app's access at the patient's direction within one hour | Functional requirement |
| (g)(10)(vii) | Receive and validate tokens the server issued | SMART App Launch token introspection |
| (g)(10)(viii) | Publish complete API documentation at a public hyperlink "without any preconditions or additional steps" | Functional requirement |
The rule names exactly which parts of SMART you need. Section 170.215(c)(2) adopts SMART App Launch 2.0.0 with mandatory support for the "Patient Access for Standalone Apps" and "Clinician Access for EHR Launch" capability sets, every capability in section 8.1.2 except "permission-online," and token introspection. Write access is out of scope. The Certification Companion Guide (CCG) confirms that (g)(10) covers "read" services only.
Certification also pulls in other criteria. Under the privacy and security framework in 45 CFR 170.550(h), a (g)(10) module must also be certified to (d)(1), (d)(9), (d)(12), and (d)(13), plus either (d)(2)(i)(A) and (B) with (d)(2)(ii) through (v), or (d)(10). Section 170.550(g) adds quality management system (g)(4) and accessibility-centered design (g)(5) for every module, and EHI export (b)(10) when the product stores electronic health information. Developers also take on the API Conditions of Certification in 170.404, including publishing service base URLs as FHIR Endpoint resources and organization details as Organization resources, collected in a Bundle and reviewed quarterly, per 45 CFR 170.404(b)(2).
Which US Core, SMART, and Bulk Data versions can you certify to?
The regulatory baseline is US Core 6.1.0 with USCDI v3, SMART App Launch 2.0.0, and Bulk Data 1.0 (the test kit uses the 1.0.1 errata). The Standards Version Advancement Process (SVAP) lets you certify to newer approved versions instead, but the test kit only supports some of them today.
HTI-1 adopted US Core 6.1.0 and SMART 2.0.0 alongside the older US Core 3.1.1 and SMART 1.0.0, and the older adoptions expired January 1, 2026. Inferno dropped them, along with US Core 4.0.0, in test kit v8.0.0 on March 9, 2026. ONC's SVAP page lists the newer versions approved for (g)(10):
| Standard | Regulatory version | SVAP-approved versions | Options in Inferno test kit (v8.1.0) |
|---|---|---|---|
| US Core / USCDI | 6.1.0 / USCDI v3 | 7.0.0 (2024), 8.0.0 (2025, with 8.0.1 errata per the CCG), 9.0.0 (2026) | 6.1.0 / USCDI v3, 7.0.0 / USCDI v4 |
| SMART App Launch | 2.0.0 | 2.2.0 (2024) | 2.0.0, 2.2.0 |
| Bulk Data Access | 1.0.0 STU 1 (1.0.1 errata) | 2.0.0 STU 2 (2022) | 1.0.1, 2.0.0 |
Two practical notes. First, ONC announced the 2026 SVAP versions on June 30, 2026, made them available for voluntary certification from August 29, 2026, and says on the same SVAP page that updated test tools and procedures will be available by December 2026. Until the kit offers a US Core 8 or 9 option, plan your test run around 6.1.0 or 7.0.0. Second, the kit's own documentation says US Core 7.0.0 should only be paired with SMART 2.0.0 or later because of its granular scope requirements. For mapping USCDI v3 elements to profiles, see our USCDI v3 requirements breakdown.
What did HTI-5 change for (g)(10)?
HTI-5 did not amend the (g)(10) criterion text. It removed the older API criteria around it and narrowed Real World Testing to the API criteria. The final rule, published October 28, 2026 at 91 FR 67916, is effective December 28, 2026, with some provisions effective January 1, 2027.
- (g)(7) application access, patient selection, and (g)(9) application access, all data request, are removed effective January 1, 2027. ONC's reasoning is that (g)(10) modules already perform the (g)(7) function through SMART App Launch.
- The expired US Core 3.1.1 and SMART 1.0.0 entries are removed from 170.215.
- From December 28, 2026, "Certified API technology" in 170.404(c) will mean modules certified to (g)(10) and the three prior authorization API criteria, (g)(31) through (g)(33). The service base URL publication requirement stays.
- From the same date, Real World Testing plans are no longer required, and results reporting covers only the (g) criteria listed in 170.405(a): (g)(10) and (g)(31) through (g)(33).
Developers of (g)(10) modules keep filing annual Real World Testing results. The revised Insights Condition in 170.407, as republished in the HTI-5 regulatory text, keeps two (g)(10) measures, with reporting starting in July 2027 for FHIR usage by user type and resource, July 2028 for the US Core version breakdown, and July 2029 for bulk data requests. Our HTI-5 final rule summary lists all 14 removed criteria.
How is the Inferno (g)(10) test kit organized?
The ONC Certification (g)(10) Standardized API Test Kit is ONC's approved test method for the criterion. It behaves like an API consumer: it runs SMART launches against your authorization server, then uses the tokens it gets to query your FHIR API. You pick a US Core, SMART, and Bulk Data version when you create a session.
As of October 31, 2026, the hosted instance at inferno.healthit.gov showed version 8.0.7 (last updated September 8, 2026), while the GitHub repository had already published v8.1.0 on October 28, 2026. ONC says updates are "released monthly," so check the release notes before you test. The v8.0.7 notes warn that a validator fix for US Core 6.1.0 means "some systems that previously passed may now fail."
The suite runs in this order:
- Standalone Patient App, Full Access: a confidential-client patient standalone launch with refresh token and OpenID Connect identity token, then a token refresh and a re-read of the Patient resource.
- Standalone Patient App, Limited Access: the same app, but the tester grants only a subset of resource types to show the patient controls scopes.
- EHR Practitioner App: an EHR launch with patient context, refresh token, and OIDC. Under SMART v2, Inferno sends the authorization request itself by POST, so your authorize endpoint must accept it (the "authorize-post" capability).
- Single Patient API: every US Core search in the CapabilityStatement, reads, profile validation, and must support coverage.
- Multi-Patient Authorization and API: SMART Backend Services authorization, a group-level
$export, and validation of every NDJSON file. - Additional Authorization Tests: public client launch with OIDC, token revocation, invalid
aud, invalid token requests, invalid PKCE code verifier, EHR launch with patient scopes, token introspection, asymmetric client launch, SMART v1 scopes, fine-grained scopes, and granular scope selection. - Visual Inspection and Attestation: items a tester confirms by watching a demo or reading your attestation, such as app registration, the authorization screen, the
offline_accessnotice, three-month refresh tokens, public documentation, TLS 1.2 or higher, and JWKS caching behavior.
What do the SMART App Launch tests check?
They check that patients and clinicians can authorize an app through the two required capability sets, that the scopes granted match what the person chose, and that the server rejects malformed requests. The Single Patient API group reuses the token and patient ID from an earlier launch, so a broken launch blocks the data tests that depend on it.
Your server must serve /.well-known/smart-configuration as JSON, appended to the FHIR base URL (for https://ehr.example.com/fhir that is https://ehr.example.com/fhir/.well-known/smart-configuration), per the SMART 2.0.0 conformance page. PKCE is mandatory: SMART 2.0.0 says servers "SHALL support the S256 code_challenge_method and SHALL NOT support the plain method," and Inferno sends a bad code verifier to confirm you refuse it. The asymmetric client test expects private_key_jwt with RS384 or ES384 signatures.
HTI-1 added granular scopes. The CCG requires that when an app asks for a resource-level Condition or Observation scope, the patient can grant sub-resource scopes instead: Encounter Diagnosis, Problem List, and Health Concern for Condition; Clinical Test, Laboratory, Social History, SDOH, Survey, and Vital Signs for Observation. Inferno's granular scope selection test requires the tester to decline the resource-level scope and grant sub-resource scopes. A scope request in the test looks like this (illustrative, wrapped for reading):
launch/patient openid fhirUser offline_access
patient/Patient.rs
patient/Condition.rs?category=http://terminology.hl7.org/CodeSystem/condition-category|encounter-diagnosis
patient/Observation.rs?category=http://terminology.hl7.org/CodeSystem/observation-category|laboratory
Your consent screen can group or rename scopes, as long as the patient can still authorize at the individual resource and sub-resource level. The CCG also requires that patients are told when an app is asking for persistent access and can refuse offline_access. Wildcard scopes are not required for patient and user scopes, and you don't have to handle a mix of SMART v1 and v2 scopes in one request.
Revocation is tested as a demo: the patient revokes the app, and Inferno confirms the earlier token gets an unauthorized response on a Patient read. The CCG lets short-lived access tokens expire instead of revoking them immediately, provided access ends within one hour.
What does the bulk data test need from your server?
It needs a working SMART Backend Services token flow and a Group whose export contains at least one resource for every USCDI-mapped US Core profile, plus Encounter, Location, Organization, and Practitioner resources. Inferno needs those four because must support references in the USCDI profiles point to them. Build the Group from synthetic patients chosen to cover every profile, then confirm the coverage before the run.
Before running, you register Inferno's JWKS URL with your authorization server. In the session you enter the Bulk Data FHIR URL, backend services token endpoint, client ID, scopes, and Group ID. Inferno then requests a token with a signed JWT client assertion and kicks off the export. The flow follows the Bulk Data 1.0.1 export spec (illustrative, fake IDs):
POST /oauth/token
Content-Type: application/x-www-form-urlencoded
grant_type=client_credentials
&scope=system/*.read
&client_assertion_type=urn:ietf:params:oauth:client-assertion-type:jwt-bearer
&client_assertion=eyJhbGciOiJSUzM4NCIs...
GET /fhir/Group/123456/$export
Accept: application/fhir+json
Prefer: respond-async
Authorization: Bearer [access_token]
HTTP/1.1 202 Accepted
Content-Location: https://ehr.example.com/fhir/bulkstatus/abc123
GET /fhir/bulkstatus/abc123 (poll: 202 while running, 200 with a JSON manifest when done)
GET [output file url from manifest]
Accept: application/fhir+ndjson
If the manifest sets requiresAccessToken to true, file downloads must carry the bearer token. The CCG also accepts capability URLs for file access. The visual inspection group asks you to attest to _since support for exports, and to show that multi-patient queries return nothing beyond the pre-authorized scopes. The CCG lets system scopes use either wildcard syntax or a list of resource scopes.
What causes (g)(10) test failures?
Inferno fails a run on missing test data as readily as on wrong code. It must see each must support element populated in at least one returned resource, subject to the CCG's version-specific exceptions, and a skipped test fails its sequence the same way a failed test does.
The test kit's FAQ explains the scoring. Inferno ignores elements that only carry a Data Absent Reason extension when it looks for must support coverage. A "skip" means your server didn't return enough data for Inferno to finish, and the sequence counts as failed. "Omit" is the only non-pass result that doesn't hurt you. Where an element allows several choices or references, the CCG requires support for at least one, documented publicly. The certification kit validates terminology inside its own test logic against local terminology files, so a stale or missing terminology build on a local install produces misleading results.
The CCG adds these rules:
- US Core Patient
name.suffixis required for testing. - Clinical note text the module creates must stay in a "plain text" form in the API response; converting it to PDF or .docx is not acceptable. Notes that came from outside systems go out in their original format, and "plain text" does not have to mean a
contentTypeoftext/plain. - For US Core 6.1.0, Organization and Practitioner need read support only, and must be reachable through references in other resources.
- You must document which US Core choices and references you support, how you enforce TLS 1.2 or higher, and how native apps get their first refresh token.
- Your documentation link must open "without any preconditions or additional steps," which is the regulation's own wording in (g)(10)(viii)(B). In practice that rules out a login, a form, or a click-through agreement.
Configuration and fixtures account for the rest of the checklist: an authorization server that caches a client's JWKS longer than its cache-control header allows, a refresh token lifetime left at a short default, or a test patient whose record has no smoking status, goal, or care team. For background on where FHIR fits relative to your HL7 v2 feeds, see HL7 vs FHIR.
Pre-test checklist mapped to Inferno test groups
Run through this list before you book time with an ONC-Authorized Testing Lab.
| Inferno test group | Have this ready |
|---|---|
| Standalone Patient App, Full Access | Inferno registered as a confidential client with its redirect URI; .well-known/smart-configuration served under the FHIR base URL; S256 PKCE; OIDC id_token and fhirUser; refresh tokens valid three months or longer, and a refresh that returns a new three-month token without re-login |
| Standalone Patient App, Limited Access | Consent screen where the tester can deselect resource types; server honors the reduced grant |
| EHR Practitioner App | Inferno registered with launch and redirect URIs; EHR launch passes launch and iss; token response includes patient context; authorize endpoint accepts POST (SMART v2) |
| Single Patient API | A test patient (or set of patients) covering every USCDI v3 profile, every must support element populated (after the CCG exceptions for your version), Provenance, name.suffix, and all required searches in the US Core 6.1.0 CapabilityStatement |
| Multi-Patient Authorization and API | Inferno's JWKS URL registered; backend services token endpoint that rejects a wrong grant_type or client_assertion_type; a Group whose export covers every profile plus Encounter, Location, Organization, Practitioner; NDJSON output validates |
| Additional Authorization Tests | Public client registration; rejection of bad aud, bad tokens, and bad PKCE verifiers; token introspection endpoint; asymmetric client support; SMART v1 and v2 scope handling; Condition and Observation sub-resource scope selection |
| Token Revocation (inside Additional Authorization Tests) | A patient-facing way to revoke an app, and access ending within one hour |
| Visual Inspection and Attestation | Live demo of app registration (single and multi-patient), the authorization screen, and the offline_access notice; public documentation URL; public service base URL Bundle; TLS 1.2+ enforcement; JWKS cache behavior; native app refresh token method |
How should you prepare before formal testing?
Run the kit yourself against a staging build loaded with complete test data until every group passes on the versions you will test with, then rehearse the visual inspection steps with someone who didn't build the system.
The repository README recommends a local install over the shared public instance, so you can test inside your network and avoid downtime. Local terminology validation needs a UMLS account, Docker with at least 10 GB of RAM, and about 40 GB of free disk. The hosted instance is for demonstration only, is not for PHI, and deletes data periodically, so use synthetic patients. The official walkthrough notes that results are not stored indefinitely, so export the report from each passing run. Inferno's reference server shows what a passing run looks like before you point the kit at your own API.
We run (g)(10) mock audits through our ONC certification readiness service, and our ONC certification engineering team builds or fixes the SMART, US Core, and Bulk Data pieces when a mock run turns up gaps. A mock audit shows you where you stand; it can't guarantee a passing result from the lab. Your first step: pick your US Core, SMART, and Bulk Data versions, create a session on the current kit release, complete the Standalone Patient App launch, and let Single Patient API run with that token against your most complete synthetic patient. Sort what it flags into data coverage, mapping, and authorization fixes, and work the data list first.