ONC compliance staff augmentation
Engineers who close your ONC certification gaps
Orisan Clinical Systems provides ONC certification staff augmentation: experienced healthcare engineers who embed with your team to build the remaining certification functionality and close the gaps between your product and a passing ONC Health IT certification test.
Our engineers join your standups, work in your repositories, and ship to your roadmap. They arrive already fluent in FHIR, US Core, SMART on FHIR, C-CDA, and e-prescribing, so your team spends its time shipping instead of reading implementation guides.
Where certification projects stall
Your roadmap cannot absorb certification
Certification work competes with customer features. Embedded engineers add capacity for the criteria without pulling your core team off the product.
The standards have a steep learning curve
US Core profiles, SMART App Launch scopes, Bulk Data exports, and C-CDA templates take months to learn well. Our engineers have already done it.
Deadlines are fixed
Real-time prescription benefit (b)(4) joins the Base EHR definition on January 1, 2028, and any product certified to (b)(3) e-prescribing must certify (b)(4) as well.
Gap analyses do not build software
A list of findings is only useful if someone closes them. We pair readiness testing with engineers who turn findings into passing results.
What our engineers build
Standardized API and interoperability
§170.315(g)(10) and related criteria
FHIR R4 APIs that conform to US Core and pass the Inferno (g)(10) test kit, including SMART App Launch, patient and multi-patient access, and Bulk Data export.
- US Core profiles and USCDI v3 data classes
- SMART App Launch 2.x authorization and scopes
- Bulk Data (FHIR Bulk Data Access) export
- C-CDA generation and transitions-of-care workflows
E-prescribing, decision support, and security
§170.315(b) and (d) criteria
Prescribing and safety functionality built by the team behind Orisan Sage, plus the privacy and security criteria every certified product needs.
- E-prescribing (b)(3) on the NCPDP SCRIPT standard
- Real-time prescription benefit (b)(4) on NCPDP RTPB
- Decision support interventions (b)(11)
- Privacy and security (d) criteria, audit logging, and encryption
From gap analysis to passing test results
- 1
Assess
Start from an Orisan readiness assessment, or from your own gap list, and agree on the criteria in scope.
- 2
Embed
Our engineers join your team, tools, and sprint cadence, working in your codebase under your direction.
- 3
Build and test
We build to the certification criteria and test continuously with Inferno and the ONC test procedures.
- 4
Go to the lab ready
A final mock audit confirms readiness before you sit for official testing with an ONC-ATL.
Standards and criteria we work with
Frequently asked questions
What is ONC certification staff augmentation?
It is an engagement where healthcare engineers join your development team to build the functionality your product needs for ONC Health IT certification. They work in your codebase, under your direction, alongside your existing engineers.
How is this service billed?
Certification engineering is billed at standard contract engineering rates for the engineers on your team. We scope the engagement with you up front based on the criteria and timeline.
What is required for (g)(10) certification?
The (g)(10) Standardized API criterion requires a FHIR R4 API that supports US Core, SMART App Launch authorization for single-patient access, and FHIR Bulk Data export for multi-patient access. Conformance is tested with the Inferno (g)(10) Standardized API Test Kit.
Does e-prescribing certification require real-time prescription benefit?
Yes. Under the HTI-4 final rule, any health IT certified to (b)(3) electronic prescribing must also be certified to (b)(4) real-time prescription benefit, and (b)(4) is part of the Base EHR definition starting January 1, 2028.
What is USCDI v3?
The United States Core Data for Interoperability (USCDI) is the standardized set of health data classes and elements that certified health IT must support. USCDI v3 has been the required baseline since January 1, 2026.
Can contractors build certified functionality?
Yes. Certification is issued to the health IT developer for the product, not to the individuals who wrote the code. Your company remains the developer of record and owns everything our engineers build.
Do your engineers sign a BAA?
Yes. When an engagement involves protected health information, we sign a Business Associate Agreement and follow HIPAA safeguards.
Guides from our engineers
Interoperability
HL7 vs FHIR: How v2, C-CDA, and FHIR Differ and When to Use EachHL7 is the standards body; v2, C-CDA, and FHIR are its standards. See how they differ, what ONC and CMS rules require in 2026, and which one fits each interface you build.
ONC Certification
Real-Time Prescription Benefit Under HTI-4: What to Build Before 2028HTI-4 adds §170.315(b)(4) real-time prescription benefit on NCPDP RTPB v13. Here is who must certify, the 2024 to 2028 deadlines, and what the build actually involves.
ONC Certification
HTI-5 Final Rule: What Changed for Certified Health IT DevelopersHTI-5 removes 14 of 60 ONC certification criteria and revises 7, not the 34 removals proposed. Here is every change, its effective date, and what developers should do before December 28, 2026.
ONC Certification
ONC g10 Certification: Passing the Inferno Standardized API Test KitWhat §170.315(g)(10) requires, which US Core, SMART, and Bulk Data versions you can test against, how the Inferno (g)(10) test kit is organized, and a pre-test checklist.
ONC Certification
ONC Health IT Certification: Requirements, Criteria, and Process in 2026A developer's map of the ONC Health IT Certification Program after HTI-5: who runs it, who needs it, the criteria groups, Base EHR, Conditions of Certification, and a preparation checklist.
ONC Certification
USCDI v3 Requirements: New Data Elements, US Core 6.1.0, and HTI-5USCDI v3 has been the only certification baseline since January 1, 2026. Here are the 24 new elements mapped to US Core 6.1.0 and the criteria that still use them after HTI-5.
Related services
ONC Certification Readiness & Mock Testing
A fixed-scope mock audit of the certification criteria you are targeting, run before you book and pay for proctored testing with an ONC-Authorized Testing Lab.
Healthcare Software Staff Augmentation
FHIR, HL7, and EHR integration engineers who embed with your team to build interoperability, prescribing, and clinical software.
Add certification capacity to your team
Tell us which criteria you are building toward and your target test date. We will propose a team and a plan.
Talk to Our Engineering Team