ONC Health IT certification is the voluntary federal program, run by the Office of the National Coordinator for Health Information Technology, that tests and certifies software against the criteria in 45 CFR 170.315. Developers test with an ONC-Authorized Testing Lab, get certified by an ONC-Authorized Certification Body, are listed on the CHPL, and must keep meeting the Conditions of Certification.
This guide reflects the program as of October 31, 2026, three days after the HTI-5 final rule was published and separates what applies today from what changes on December 28, 2026 and January 1, 2027. We build and audit certified health IT, and the opinions here come from that work.
What is ONC Health IT certification?
ONC writes the criteria and standards, independent labs test products against them, and authorized certification bodies issue the certification. CMS programs depend on it, and many health system buyers ask for it.
The legal basis is section 3001(c)(5) of the Public Health Service Act, which provides for "the voluntary certification of health IT." The 21st Century Cures Act added the Conditions and Maintenance of Certification, so certification now covers developer behavior (information blocking, API terms, attestations) as well as product features.
The criteria live in 45 CFR 170.315 and the definitions, including Base EHR, in 45 CFR 170.102.
Is it ONC or ASTP/ONC?
It is ONC again. In July 2024 HHS added the Assistant Secretary for Technology Policy title, and for about two years the office signed documents as ASTP/ONC. A Federal Register notice published April 1, 2026 removed that title and "restores the Office of the National Coordinator for Health Information Technology (hereafter referred to as ONC) as a singularly titled office." HTI-5 then struck the remaining ASTP references from 45 CFR 170.523 and part 172. Older fact sheets, including the HTI-4 ones, still say ASTP/ONC; the rules are the same.
Who needs ONC certified health IT?
Developers need it when their customers participate in CMS programs that require certified EHR technology (CEHRT), or when buyers require it in contracts. The biggest driver is CMS: eligible hospitals and critical access hospitals in the Medicare Promoting Interoperability Program, and clinicians reporting the MIPS Promoting Interoperability performance category, must use CEHRT, and their program scores and payment adjustments depend on it.
CMS is specific about timing. On its CEHRT page it says "the CEHRT functionality must be in place by the first day of the EHR reporting period and the product must be certified by ONC by the last day of the EHR reporting period." A lapse in your certification becomes your customers' reporting problem.
Health system and practice procurement teams often list specific criteria as requirements, such as (g)(10) for FHIR API access or (b)(10) for electronic health information export. Electronic prior authorization adds a new reason. The (g)(31) to (g)(33) criteria let providers connect to the prior authorization APIs that CMS required of impacted payers in CMS-0057-F, which covers medical items and services and excludes drugs. Drug prior authorization runs through NCPDP SCRIPT transactions inside (b)(3). Promoting Interoperability participants will report an electronic prior authorization measure beginning in 2027, according to the HTI-4 overview and key dates fact sheet.
Who runs the program: ONC, testing labs, certification bodies, and the CHPL
ONC sets the rules. ONC-Authorized Testing Laboratories (ONC-ATLs) test conformance, ONC-Authorized Certification Bodies (ONC-ACBs) decide certification and run surveillance, and the CHPL publishes the result.
| Party | What it does | What you deal with |
|---|---|---|
| ONC | Adopts criteria and standards by rule, approves test methods, authorizes labs and certification bodies, and can directly review certified health IT | Rules, test methods, direct review |
| ONC-ATL | Tests a Health IT Module against the approved test procedures and test tools for each criterion | Scheduling, demonstrations, tool output |
| ONC-ACB | Reviews the test results and documentation, issues the certification, and conducts surveillance after certification | Application, disclosures, attestations, surveillance |
| CHPL | The public list of every certified product and its criteria | Your public listing |
ONC calls the Certified Health IT Product List "a comprehensive and authoritative listing of all certified health information technologies that have been successfully tested and certified." Each listing shows the certified criteria, the product version, and any SVAP standard versions the developer has adopted.
The CHPL also generates the CMS EHR Certification ID that hospitals and clinicians report to CMS. ONC's quick reference says the ID can represent one product or several that together satisfy 100% of the Base EHR definition for a reporting year, and that a new ID "should be generated for each applicable reporting year, even if the underlying product(s) do not change." To verify a product, search the CHPL for the exact product and version and confirm each criterion your customer needs is listed and the certification is active.
Testing labs and certification bodies are private organizations authorized by ONC, which lists them on its Certification Program pages.
What are the ONC certification criteria for health IT?
The criteria are the numbered paragraphs of 45 CFR 170.315, grouped by letter. The current eCFR text has 60 criteria in effect. HTI-5 removes 14 of them across two effective dates, so 46 remain on January 1, 2027.
| Group | What it covers | In effect, Oct 2026 | After HTI-5 (Jan 1, 2027) |
|---|---|---|---|
| (a) Clinical | CPOE for medications, labs and imaging; drug-drug and drug-allergy interaction checks; demographics; implantable device list; social, psychological and behavioral data | (a)(1) to (a)(5), (a)(9), (a)(12), (a)(14), (a)(15): 9 | (a)(1) to (a)(5), (a)(14), (a)(15): 7 |
| (b) Care coordination | Transitions of care (C-CDA), reconciliation, e-prescribing, real-time prescription benefit, EHI export, decision support interventions | (b)(1) to (b)(4), (b)(7) to (b)(11): 9 | (b)(1) to (b)(4), (b)(10), (b)(11): 6 |
| (c) Clinical quality measures | Record and export, import and calculate, report (QRDA) | (c)(1) to (c)(4): 4 | (c)(1) to (c)(3): 3 |
| (d) Privacy and security | Authentication and access control, auditable events, audit reports, amendments, automatic time-out, emergency access, end-user device encryption, integrity, trusted connection, auditing actions on health information, accounting of disclosures, encrypted authentication credentials, multi-factor authentication | (d)(1) to (d)(13): 13 | (d)(1) to (d)(13): 13 |
| (e) Patient engagement | View, download, and transmit; patient health information capture | (e)(1), (e)(3): 2 | (e)(1): 1 |
| (f) Public health | Immunization registries, syndromic surveillance, electronic lab reporting, cancer registries, electronic case reporting, antimicrobial use and resistance, health care surveys | (f)(1) to (f)(7): 7 | (f)(1) to (f)(7): 7 |
| (g) Design and performance, and APIs | Safety-enhanced design, quality management system, accessibility-centered design, the (g)(10) FHIR API, and the three prior authorization APIs | (g)(1) to (g)(7), (g)(9), (g)(10), (g)(31) to (g)(33): 12 | (g)(3) to (g)(5), (g)(10), (g)(31) to (g)(33): 7 |
| (h) Transport methods | Direct Project messaging, edge protocols, XDR/XDM | (h)(1), (h)(2): 2 | None |
| (j) Modular API capabilities | Workflow triggers for decision support interventions (client) and Subscriptions (client), added by HTI-4 | (j)(20), (j)(21): 2 | (j)(20), (j)(21): 2 |
| Total | 60 | 46 |
Starting December 28, 2026, the (h) group is gone, so the standalone Direct transport criteria no longer exist, although (b)(1) keeps its edge protocol requirement until January 1, 2030. The (j) group is newer than most documentation: HTI-4 added it so the prior authorization API criteria could reference modular client capabilities through cross-reference.
Not every criterion stands alone. ONC's process page lists the dependencies: privacy and security requirements under §170.315(d) apply to the criteria you certify; (g)(4) quality management system and (g)(5) accessibility-centered design attach to functional criteria generally; (g)(3) safety-enhanced design applies only to the criteria it names, which after HTI-5 are (a)(1) to (a)(5), (a)(14), (b)(2), (b)(3), and (b)(11); and under §170.402(a)(4) a module that is part of a product that electronically stores EHI must also certify to (b)(10) EHI export.
Which criteria did HTI-5 remove and revise?
HTI-5 removed 14 criteria and revised 7. The removals take effect in two batches, December 28, 2026 and January 1, 2027, under amendatory instructions 11 and 12 of the final rule.
| Criterion | Name | HTI-5 action | Effective |
|---|---|---|---|
| §170.315(a)(9) | Clinical decision support (CDS) | Removed | Dec 28, 2026 |
| §170.315(b)(7) | Security tags, summary of care, send | Removed | Dec 28, 2026 |
| §170.315(b)(8) | Security tags, summary of care, receive | Removed | Dec 28, 2026 |
| §170.315(b)(9) | Care plan | Removed | Dec 28, 2026 |
| §170.315(g)(6) | Consolidated CDA creation performance | Removed | Dec 28, 2026 |
| §170.315(h)(1) | Direct Project | Removed | Dec 28, 2026 |
| §170.315(h)(2) | Direct Project, Edge Protocol, and XDR/XDM | Removed | Dec 28, 2026 |
| §170.315(a)(12) | Family health history | Removed | Jan 1, 2027 |
| §170.315(c)(4) | Clinical quality measures, filter | Removed | Jan 1, 2027 |
| §170.315(e)(3) | Patient health information capture | Removed | Jan 1, 2027 |
| §170.315(g)(1) | Automated numerator recording | Removed | Jan 1, 2027 |
| §170.315(g)(2) | Automated measure calculation | Removed | Jan 1, 2027 |
| §170.315(g)(7) | Application access, patient selection | Removed | Jan 1, 2027 |
| §170.315(g)(9) | Application access, all data request | Removed | Jan 1, 2027 |
| §170.315(b)(1) | Transitions of care | Revised: C-CDA send and receive, display, and create requirements expire January 1, 2030; C-CDA validation stays | Dec 28, 2026 |
| §170.315(b)(2) | Clinical information reconciliation and incorporation | Revised | Dec 28, 2026 |
| §170.315(b)(11) | Decision support interventions | Revised: source attributes, source attribute access and modification, and intervention risk management requirements removed | Dec 28, 2026 |
| §170.315(c)(3) | Clinical quality measures, report | Revised | Dec 28, 2026 |
| §170.315(e)(1) | View, download, and transmit to 3rd party | Revised and republished | Dec 28, 2026 |
| §170.315(f)(6) | Antimicrobial use and resistance reporting | Revised | Dec 28, 2026 |
| §170.315(g)(3) | Safety-enhanced design | Revised | Dec 28, 2026 |
The proposed rule, published December 29, 2025, would have removed 34 criteria. ONC kept 20 of those, including (a)(14) implantable device list, (b)(2) reconciliation, (f)(4) cancer registries, and (f)(7) health care surveys. Pages written in early 2026 may still describe the proposed list. The criterion-by-criterion breakdown of the HTI-5 final rule goes through each change and what it means for products already in testing.
What is the Base EHR definition?
Base EHR is the minimum set of certified capabilities a product must have for CMS programs to count it as an EHR. Until December 28, 2026 it also includes (g)(7), (g)(9), and (h)(1) or (h)(2). From that date it is §170.315(a)(1), (2), or (3), plus (a)(5), (a)(14), (b)(1), (b)(11), (c)(1), and (g)(10). On January 1, 2028, (b)(4) real-time prescription benefit joins the list.
The definition sits in 45 CFR 170.102. It has moved several times, and the history explains a lot of stale documentation:
- Under HTI-1, the old (a)(9) CDS criterion was replaced by (b)(11) decision support interventions. The definition accepted (a)(9) or (b)(11) through December 31, 2024, and required (b)(11) on and after January 1, 2025.
- Until HTI-5, paragraph (3)(i) also required (g)(7), (g)(9), and (h)(1) or (h)(2).
- HTI-4 added paragraph (3)(iv), which requires (b)(4) on and after January 1, 2028.
- HTI-5, effective December 28, 2026, rewrote (3)(i), moved (b)(11) into it, and reserved (3)(ii) and (3)(iii) because their transition dates had passed. It did not touch (3)(iv), so the 2028 RTPB requirement stands. ONC proposed dropping (a)(14) from the definition but kept it, because it kept the criterion.
Base EHR is a floor. CMS's CEHRT definition adds program-specific criteria on top of it, so check the CMS program rules for the reporting year you care about. ONC noted in HTI-5 that removing criteria from Base EHR does not by itself change what CMS requires, and that it is coordinating with CMS on timing.
What are the Conditions and Maintenance of Certification?
They are ongoing obligations in 45 CFR 170.401 through 170.407 that bind the company as well as the product, and ONC can open a direct review when it believes a developer has not met one.
| Section | Condition | What it requires, after HTI-5 |
|---|---|---|
| §170.401 | Information blocking | Do not engage in information blocking as defined in 45 CFR part 171 |
| §170.402 | Assurances | Do not interfere with use of certified capabilities; developers subject to the EHI export assurance must provide customers health IT certified to (b)(10) |
| §170.403 | Communications | Do not prohibit or restrict communication about the usability, interoperability, or security of your health IT, users' experiences, or related business practices |
| §170.404 | Application programming interfaces | For (g)(10) and the (g)(31) to (g)(33) prior authorization APIs: publish complete business and technical documentation and all terms and conditions, including fees, at a public link, and allow access without special effort |
| §170.405 | Real world testing | Test real-world use annually for covered criteria; plans are no longer submitted, and full results reporting applies only to API criteria |
| §170.406 | Attestations | Attest to compliance with the Conditions semiannually |
| §170.407 | Insights | Developers with (g)(10) and at least 50 hospital sites or 500 individual clinician users report two FHIR measures, use of FHIR in apps and use of FHIR bulk data access; others submit an attestation that they do not qualify |
Is Real World Testing still required after HTI-5?
Yes, in a smaller form. HTI-5 removed the annual Real World Testing plan submission and limited full results reporting to Health IT Modules certified to the API criteria: (g)(10), (g)(31), (g)(32), and (g)(33). The obligation to test the real-world use of modules certified to the criteria listed in §170.405(a) remains.
The rule also drops the requirement to list SVAP updates in results reports for non-API criteria, since the CHPL and attestations already show them. ONC said it will apply the new approach starting with the attestation period that begins January 1, 2027. This finalizes the position ONC took in its June 30, 2025 enforcement discretion notice.
HTI-5 also cut the Insights Condition. It removed five of the seven measures (individuals' access, C-CDA reconciliation, applications supported, and two immunization measures) and kept "use of FHIR in apps" and "use of FHIR bulk data access." Both remaining measures apply only to developers with (g)(10)-certified modules who meet the minimum reporting threshold in §170.407(a)(2). Reporting on the bulk data measure now starts in July 2029 instead of July 2028.
Did HTI-5 change information blocking?
No. The proposed rule included information blocking changes, but ONC did not finalize any of them in HTI-5 and said the remaining proposals are still under review. Reed Smith's analysis describes ONC as having "deferred every proposed change to the information blocking rule." The §170.401 Condition and part 171 apply as before.
How does the ONC certification process work?
You pick your criteria, build to the standards, self-test with the official tools, test with an ONC-ATL, get the certification decision from an ONC-ACB, and then maintain the listing. ONC's certification process page lays out the steps, starting with the note that "it is up to the developer to determine for what criteria they wish to seek certification."
- Scope the module: the criteria the product will carry plus every dependent criterion. Use the eCFR and HTI-5 text, since some ONC worksheets dated before October 2026 still list removed criteria.
- Read the test method for each criterion: test procedures, Certification Companion Guides, test tools, and test data. Passing a tool does not settle conformance alone, because certification covers the full scope of the criterion and the Companion Guides record ONC's clarifications of that scope.
- Build to the adopted standards. For (g)(10) that means FHIR R4 (4.0.1), US Core 6.1.0, SMART App Launch 2.0.0, Bulk Data Access 1.0.0, and USCDI v3, as adopted in 45 CFR 170.215 and 170.213. SVAP lets you certify to newer versions ONC has approved.
- Self-test with the official tools until they pass cleanly and repeatably. For (g)(10) that is the Inferno (g)(10) Standardized API Test Kit.
- Register with an ONC-ATL and an ONC-ACB, submit documentation, and publish the required public API documentation, terms, and fees.
- Test with the lab: live demonstrations for functional criteria, tool runs for standards-based ones. A failure usually means retesting that criterion.
- The ONC-ACB issues the certification and the product appears on the CHPL.
- Maintain it: semiannual attestations, Real World Testing where it applies, Insights reporting if you qualify, surveillance, and CHPL updates when the product or standards change.
After certification, ONC-ACBs "must conduct surveillance to determine if a Health IT Module it certified continues to function as required by its certification," according to ONC's oversight and surveillance page. ONC itself can open a direct review when a nonconformity may present a serious risk to public health or safety, or when it believes a developer has not met a Condition of Certification. ONC and ONC-ACBs then work with the developer to remedy a nonconformity across all customers.
What does the (g)(10) API test look like?
Version 8.0.7 of the Inferno (g)(10) test kit, updated September 8, 2026, is listed as an approved test method. It tests US Core 6.1.0 with USCDI v3 and US Core 7.0.0 with USCDI v4, SMART App Launch 2.0.0 and 2.2.0, and Bulk Data 1.0.1 and 2.0.0. It covers standalone and EHR launch, every US Core profile, required searches, Must Support elements, and multi-patient bulk export. You can run it hosted on healthit.gov (no PHI) or self-host it from the GitHub repository.
In the projects we see, (g)(10) takes the most engineering effort of any single criterion, and it gets the most attention after certification because Real World Testing results reporting and the remaining Insights measures now center on FHIR APIs. The guide to passing (g)(10) with the Inferno test kit maps the test groups to the build work, and the USCDI v3 requirements guide covers the data elements behind US Core 6.1.0.
What did HTI-1, HTI-4, and HTI-5 change?
HTI-1 modernized the program and set USCDI v3 as the baseline. HTI-4 updated e-prescribing and added real-time prescription benefit and electronic prior authorization criteria. HTI-5 cut the program from 60 criteria to 46 and reduced the reporting burden.
HTI-1 was published January 9, 2024, and a correction notice moved its effective date to March 11, 2024. According to ONC's HTI-1 summary, it dropped the "2015 Edition Cures Update" label in favor of edition-less certification, adopted USCDI v3 as the baseline as of January 1, 2026, created the (b)(11) decision support interventions criterion with its algorithm transparency requirements, and created the Insights Condition.
HTI-4 was published inside the FY 2026 IPPS final rule (CMS-1833-F) and took effect October 1, 2025. It updated (b)(3) e-prescribing to NCPDP SCRIPT 2023011, added (b)(4) real-time prescription benefit on the NCPDP RTPB standard version 13, added the (g)(31), (g)(32), and (g)(33) prior authorization API criteria built on the Da Vinci CRD, DTR, and PAS implementation guides, and added the (j)(20) and (j)(21) modular criteria. A module presented for certification to (b)(3) must also be certified to (b)(4), and modules already certified to (b)(3) must complete (b)(4) certification by January 1, 2028. HTI-5 left all HTI-4 criteria unchanged. The HTI-4 and real-time prescription benefit guide covers the e-prescribing build in detail.
HTI-2 and HTI-3 did not change the criteria. The HTI-3 final rule, published December 17, 2024, added the Protecting Care Access exception to the information blocking rules. The HTI-2 final rule (89 FR 101772, December 16, 2024) codified TEFCA provisions in 45 CFR part 172, HTI-4 finalized a subset of the remaining HTI-2 proposals, and HHS withdrew the rest on December 29, 2025.
For HTI-5, ONC estimates $1.55 billion in present-value cost savings in the rule's regulatory impact analysis, and the HTI-5 page on healthit.gov links the overview and criteria fact sheets.
| Date | What happens |
|---|---|
| Jan 9, 2024 | HTI-1 final rule published (effective Mar 11, 2024, after a correction) |
| Jan 1, 2025 | Base EHR requires (b)(11) decision support interventions in place of (a)(9) |
| Oct 1, 2025 | HTI-4 effective; optional (b)(3) transactions removed |
| Dec 29, 2025 | HTI-5 proposed rule published (34 removals proposed) |
| Jan 1, 2026 | USCDI v3 becomes the only USCDI baseline |
| Apr 1, 2026 | HHS notice restores the ONC name |
| Aug 29, 2026 | 2026 SVAP standards, including USCDI v6, available for voluntary use |
| Oct 28, 2026 | HTI-5 final rule published |
| Dec 28, 2026 | HTI-5 effective; first seven criteria removed; seven criteria revised |
| Jan 1, 2027 | Second seven criteria removed; reduced Real World Testing reporting applies to the attestation period starting this date |
| 2027 | Promoting Interoperability electronic prior authorization measure begins |
| Dec 31, 2027 | End of (b)(3) transition; modules must support SCRIPT 2023011 |
| Jan 1, 2028 | (b)(4) joins Base EHR; (b)(3) modules must also be certified to (b)(4) |
| Jul 2029 | Insights reporting on use of FHIR bulk data access begins |
| Jan 1, 2030 | (b)(1) C-CDA send, receive, display, and create requirements expire |
How long does ONC certification take?
It depends mostly on how ready the product is before you book the lab. Building to the standards, self-testing until the tools pass, and writing documentation take far longer than the test appointment.
To estimate your own schedule, work through these factors for each criterion:
- How many criteria you carry, including dependent criteria you did not plan for. A team scoping only (g)(10) still has to account for the (d) privacy and security criteria and the API documentation and terms that §170.404 requires.
- Whether the product already passes the official test tools. Inferno failures on token refresh, scopes, or Must Support elements are cheap to find on your own servers and expensive to find in front of a lab.
- Lab and certification body availability, especially near deadlines such as January 1, 2028.
- Documentation. Safety-enhanced design reports, quality management system descriptions, accessibility statements, and public API disclosures are often the last things written.
ONC does not publish an average duration. A practical estimate comes from counting the criteria still failing official tools, the documents not yet written, and the lab dates actually available, then adding time for one retest. A mock audit of a few criteria usually takes days to weeks and produces that count directly.
How to prepare for ONC certification: a checklist
The list follows the rules as they stand after HTI-5 takes effect.
- List the criteria your customers need, by CMS program and by contract. Confirm each one still exists after HTI-5 using the eCFR and the rule text.
- Add the dependencies that apply: (d) privacy and security, (g)(4) and (g)(5), (g)(3) for the criteria it names, (b)(10) if your product electronically stores EHI, (j)(20) for (g)(31), and (j)(21) for (g)(33).
- Check Base EHR. If your customers count your product as their EHR, confirm you cover the definition in force for each reporting period: (g)(7), (g)(9), and (h)(1) or (h)(2) still count until December 28, 2026, and (b)(4) is required from January 1, 2028.
- Pin the standard versions. For each criterion, write down the version in 45 CFR 170.299 and any SVAP version you intend to use.
- Assign an owner per criterion and download its test method.
- Run the official tools against a stable test environment. For (g)(10), get a clean Inferno run on every test group, twice, from a fresh configuration.
- Write the documentation: safety-enhanced design, quality management system, accessibility-centered design, and the public API documentation, terms, and fee disclosures.
- Plan the Conditions work: who signs semiannual attestations, how Real World Testing for (g)(10) and any prior authorization APIs will be run and reported, and whether you meet the Insights reporting threshold or will file the non-qualification attestation.
- Run a mock audit: someone who did not build the feature walks each test procedure as a lab would and records every gap.
- Book the lab and certification body only after the mock audit comes back clean, and leave room in the schedule for one retest.
Where to start this week
Pull your current CHPL listing and compare it line by line with the post-HTI-5 criteria table above. Mark each criterion as removed (its certification requirements end on December 28, 2026 or January 1, 2027, depending on the batch, so keep it conformant until then), revised (the §170.315 introductory text requires you to update the module and ship the update to customers by the dates set for each revised criterion and standard; ask your ONC-ACB what that means for your listing), or needed by January 1, 2028. First-time applicants can run the same exercise against the criteria their customers ask for.
If you want an outside read before you commit lab time, our ONC certification readiness mock audits cover up to three criteria, or up to five with a gap analysis, and they are meant to find problems before a lab does. No mock audit can guarantee a passing result. For the build itself, see ONC certification engineering.